psfascii format
when i write a netlist for the noise analysis, the output file noise.noise includes the following data :"freq" 1.00000"M0" (0.000000.000001.42844e-154.95885e-114.95900e-11)"R0"...
View ArticleTransient simulation - varying accuracy
I'm simulating two circuits together that have very different time resolution requirements (ms vs. ns). I need the first circuit to settle, which takes up to 100 ms. During this time, I'm happy just to...
View ArticleDifferent Monte Carlo Setups in the same run/run plan (Maestro)
I am trying to test different monte carlo setups where- In one test (call this nominal) design variables (such as the supply voltages) are kept constant and only device parameters are changing with the...
View ArticleCadence Schematic - hotkey for hiding terminal & instance labels
How to configure cdsinit for enabling custom hotkey in Cadence Schematic for hiding terminal & instance labels? For example, to remove probed nets, I havehiSetBindKey("Schematics" "0"...
View ArticleCadence Maestro - customizing results menu
Maestro results > right click on particular corner results > Customize Menus option is not working. It's not adding any options when selected & tried to add. Just empty box. I want to add DC...
View Articlefinal original layout for Parasitic Aware Design Flow RAK
I cannot find the final original layout in the folder.My plan is I want to do extraction by myself.The extracted results and other layout are there except the one that I am looking for.or is there any...
View ArticleCellview generation from VHDL code in cadence 618
HI,A beginer here for cadence,I copy paste a wkng VHDL code from Vivado to cadence VHDL editor (Libray manager->file->new cellview : ... type :VHDL, open with : editor), save -> build a...
View ArticleReading data from a file and assign those into a parametric array in verilogAMS
Dear All,I want to read data from a file and assign those into a parametric array in verilogAMS.How can it be done ?Kind Regards
View Articleskill command for remove of a netTrace
I try to config bindkeys for Net Tracer, press <Key>1 to light a trace by left-click, these two work well:hiSetBindKey("Layout" "<Key>1" "lntHiNetTracer()")hiSetBindKey("Layout"...
View Articlehow to remove the removed cell item from config view list
Hi,The config view is setup from beignning. Then afterwards some cells are removed from the schematic, and config view detects such removal and display the item as Ixxx (**None** **None** **None**)Is...
View ArticleExtending a tran sim?
I thought I would extend a transient simulation.From memory, it is a simple process of adding the "writefinal" file into "readns", and the new simulation should take over from where the prior one...
View ArticleSaving State in Maestro View as a Spectre State to Open in ADE L/XL/Midas
I have seen it is possible to migrate an existing state from ADE L/XL to Maestro (to Explorer/Assembler, respectively). If a file was originally created as a maestro view, is there a reverse process to...
View ArticleCan I use dynamic variable names in Spectre?
Hello,I have a sub circuit which is created using a script. When I instantiate it via Virtuoso, I use a CDF parameter "id" which is a numeric value.Inside the netlist for this sub circuit, I would like...
View Articleadel can not sub jobs when I install lsf patch...
Hi,adel & adeGXL can sub jobs when I install lsf patch lsf10.1_lnx310-lib217-x86_64-509238 ,but adel & adeGXL can not sub jobs when install lsf patch lsf10.1_lnx310-lib217-x86_64-601088 or...
View ArticleGetting pulse width values with cross function (non-periodic signal) using...
Hi all.I want to get a vector of pulse width values for a non-periodic square signal using Calculator.I'm using cross() function to perform measurements in the following way:cross(VT("/p10keV1") 1.65 1...
View ArticleResults Display Window
how to show specific parameter in the Results Display Window instead of showing all the parameter (i.e. i want to display only cgs, region, gm, id and vds)
View ArticleMaestro config sweep causing changes netlisting for bus "
When running my simulation in Maestro without a config sweep, there is no issue.When I run a config sweep that removes a cell that contains saved nodes, the save portion of the input.scs changes the...
View ArticleProblem with calibre RVE Highlights
Hi everyone.I'm having problems when selecting and error in calibre LVS RVE, and I trying to delete the highlights with F4 or toolbar option.Everytime I try it, I get this error. And I have to restart...
View ArticleCadence Schematic - customizing DC Operating Points annotation permanently
I can customize operating points displayed on schematic temporarily using Annotation Setup. There is a option to save the setup. On relaunching Cadence or for different schematic, I have to setup...
View ArticleHow To achieve pulse supply voltage with four different levels of voltage
Hi Everyone I am new to using cadence. I want to have a pulse supply voltage with four different levels of voltage (Let's say V0 V1 V2 V3). each voltage level stands for a specified period (let's say...
View Article