Assembler: How to achieve a trimming with calcVal for a corner analysis, e.g. for process , T and Vdd?

$
0
0

Hi,

I managed to implement a trimming with calcVal and using?&cornerName "Nominal" for Monte-Carlo. I need to trim at typ. T and Vdd, and it works great. However, next I want to create a setup for the corner run, with trimming for all different process corners (like FF, SS) vs T and Vdd, for trim done at nom. T and nom. Vdd.

However, it looks very difficult, although initially I thought matched params or 1st point option could help.

Here is an overview: Corner setup like p(TT,SS,..)+T(27,125)+Vdd(nom,max)

                  TT+27C+Vddnom                          TT + 125C + Vddmax            FF+27C+Vddnom    FF+125C+Vddmax

TrimTest      run it                                         no need to run                                 run it                  no need to run

VerifTest   take calcVal from the above      take fromTTS + 27C+Vddnom     take from above      take from FF+27C+Vddnom

Can anybody tell me how to setup calcVal for this?

Alternatively, I could also setup corners only for process, but use a sweep for T and Sweep. The disadvantage here would be that I would not be able for sweep parameters with having pass/fail for T and Vdd.

Bye Stephan