Dear Andrew,
I used the save and restart options in the ams simulator. I have set the snapshot and save times in the first simulation, in this simulation I set the stop time to 1.5ms and the supply voltage 'VDD' equal to 1.8V in the tran analyses. Then I run the second simulation with restart from option, but in this simulation I changed the stop time to 1.7ms and the supply voltage 'VDD' to 2V. After the second simulation ,I ploted the waveform of supply volltage 'VDD' , the waveform from 0 to 1.5ms is diplayed and the value of the supply voltage also equals 1.8V. Why isn't the waveform from 0 to 1.7ms diplayed and the supply voltage equal to 2V? (The output format is sst2)
Thanks!
Best Regard,
nnlt.