Quantcast
Channel: Cadence Custom IC Design Forum
Viewing all articles
Browse latest Browse all 4912

Issues with using abEyeCross.il (giving WRONG results when compared to EYE-Diagram)

$
0
0

Dear All,

 I am using abEyeCross.il from solution 11395772(https://support.cadence.com/apex/ArticleAttachmentPortal?id=a1Od0000000nX0ZEAU&pageName=ArticleContent).

This is to find peak-to-peak Deterministic jitter (DJ) when I give a supply sinusoidal noise ( of 20 mV amplitude and 11.11 MHz frequency).

I am giving a PRBS pattern of UI=31.25 pS as the input data stream. I am now finding the DJ in the output data stream.

I am trying to verify that whether  abEyeCross.il is giving correct result when I compare manually the Deterministic jitter from the actual Eye-Diagram.

But, Looks like I am getting wrong result from abEyeCross.il.

Can anybody please tell why it is giving wrong results. I am also posting the both way results below.

 abEyeCross.il Results:-

I use the commands in CIW as below:-

jit=abEyeCross(vtime('tran "/rxleq_lpbk") 0n 105n 31.25p 0 "rising")
srrWave:0x33bed0a0
DJ=peakToPeak(jit)


DJ=3.123789e-11 =31 pS



I got DJ = 31 pS

Below shows the DJ value I got from Eye-Diagram:-


Viewing all articles
Browse latest Browse all 4912

Trending Articles