Saving and plotting internal signals within the DSPF extracted view in ADE Explorer

$
0
0

I've tried to follow up the steps shown in this old topic (https://community.cadence.com/cadence_technology_forums/f/custom-ic-design/42364/saving-net-voltage-and-pin-currents-at-block-level-and-also-saving-current-in-the-mos-transistors-pins-in-extracted-view)

I've simulated a DSPF extracted view of a cell view using spectre from virtuoso IC6.1.8-64b.500.22

Using Outputs>Save all>Save Options>Select signals to output (save) selecting "allpub" there isn't problem, because you can access the internal signals of the extracted view on the Tools>ResultsBrowser menu, and send to calculator to see how to reference the signals.
My issue is when trying to avoid saving all the signals in circuit and to include a "save_signals.scs" file such as:

save I0.Xi_pm/ro_src_11
save I0.Xi_pm/enable_11

I have not found where these signals are saved. Just to include only the signals I need on the file and then use them. I haven't understand this sentence " An easy trick is to grab your saved nets/terminals from the results database", because I access de spf in the reprobrowser but signals don't appear.
Thanks,
Regards.