Hello everyone,
I have two design variables(amp,pw) that have special ranges. Amp is [0.05,0.8], pw is [10p,1n], and I want to sweep these two variables use monte carlo in adexl instead of normal sweep with uniform distance. I just dont know whether what I have done is right or not...
I wrote a .scs file, and included it in corners setup:
statistics {
process {
vary amp dist=unif N=0.45
vary pw dist=unif N=490e-12
}
}
And I'm not sure about how to set a sampling range for these two parameters. In the spectre user guide, I found this:
So in global variable settings, I set pw to 500p, and amp to 0.5 to set the "mean" in the previous picture. And the range of two parameters are [500p-490p,500p+490p] and [0.5-0.45,0.5+0.45],right? And I didnt set design variables in the corners setup.
So is my settings right? Thanks for your reply and suggestions in advance.
Regards,