I'm trying to use ADE-XL to sweep "input voltage" for a current drivability for regulator .
I select 'From/To' in the 'Parameterize' and then select 'Linear @Step Type' for input voltage sweep.
ADE-XL works correctly if:
- I don't set any Parameters
- Set a single value in the Parameters
ADE-XL results in "netl err" if:
- I set any type of specification for the parameter.
- The specific error in the log is:
\o
\o *Info* Run start for Point ID (18 1) on testbench [
\o GF130BCD_PUMP_REGULATOR:zIMSI_VPASSPMP_PUMP_4STG_4PF:1 ].
\o
\o Resetting statistical vars
\o
\o *Info* Setting parameter values ...
\o
\o Setting var period = "25n"
\o Setting var pvdd = "2.3"
\o Setting var pvpass = "5"
\o Setting temp(T) = 27
\o Setting var tr = "100p"
\o
\o *Info* Netlist Directory =
\o /home/hsjeong/simulation/GF130BCD_PUMP_REGULATOR/zIMSI_S_VPASSPMP_PUMP_4STG_4PF/adexl/results/data/Interactive.41/1/GF130BCD_PUMP_REGULATOR:zIMSI_VPASSPMP_PUMP_4STG_4PF:1/netlist
\o
\o
\o *Info* Data Directory =
\o /home/hsjeong/simulation/GF130BCD_PUMP_REGULATOR/zIMSI_S_VPASSPMP_PUMP_4STG_4PF/adexl/results/data/Interactive.41/1/GF130BCD_PUMP_REGULATOR:zIMSI_VPASSPMP_PUMP_4STG_4PF:1
\o
\o
\o *Info* Creating Netlist for Point ID (18 1)
\o
\o generate netlist...
\o Begin Incremental Netlisting Aug 1 23:21:38 2019
\o ERROR (OSSHNL-903): Failed to generate a netlist because terminal 'SUB' of instance 'MN0' in cellview
\o 'GF130BCD_PUMP_REGULATOR/zIMSI_S_VPASSPMP_PUMP_DOUBLER_5VMOS_4pF/schematic' is unbound. Do Check and Save for a schematic cellview, and for
\o other views, check and fix the design before trying to generate the netlist
\o again.
\o
\o ERROR (OSSHNL-903): Failed to generate a netlist because terminal 'B' of instance 'MN0' in cellview
\o 'GF130BCD_PUMP_REGULATOR/zIMSI_S_VPASSPMP_PUMP_DOUBLER_5VMOS_4pF/schematic' is unbound. Do Check and Save for a schematic cellview, and for
\o other views, check and fix the design before trying to generate the netlist
\o again.
\o
How to fix it? please help me.
I recently installed a new PDK.